The GSD NovaPrime® IVD RNA Extraction AE1 kit is intended for the automated extraction of genomic SARS-CoV-2 RNA from human respiratory (nasal wash/swab, nasopharyngeal wash/swab, oropharyngeal swab) specimen types, specifically validated for use with the KingFisherTM Flex System automation platform. 

The kit should be regarded as “For in-vitro diagnostic use only”.

Ideal for use with our GSD NovaPrime® SARS-CoV-2 (COVID-19) RT-PCR clinical IVD assay for virus detection.

In order to detect virus particles in human swab samples from nasal or nasopharyngeal swab specimens, the virus itself as well as the respective RNA need to be isolated prior to subsequent real-time RT-PCR analysis by approved clinical analytical kits.

Eurofins Technologies’ GSD NovaPrime® IVD RNA Extraction kits are an automated, magnetic bead extraction method for the isolation of high-quality RNA from clinical swabs. The automated workflows have been optimized for an efficient and reliable process which ensures the removal of potential inhibitors from sample matrices.

The GSD NovaPrime® IVD RNA Extraction AE1 kits are intended for automated extraction of genomic SARS-CoV-2 RNA from human respiratory (nasal wash/swab, nasopharyngeal wash/ swab, oropharyngeal swab) specimen types. The test kits are validated for the use with the KingFisher™ Flex System automation platforms.* 

* Compatibility testing with several other open-platform extraction instruments is underway.

The kits have to be validated as required by local legislation for their intended use by authorized clinical testing laboratories.

Test Principles

GSD NovaPrime® RNA Extraction AE1 and AE2 kits isolate viral RNA using magnetic-bead extraction.

1. Lysis and inactivation of viral particles
2. Binding and purification of viral RNA
3. Elution of RNA from magnetic beads

More Information
SKU 5524401101
No. of reactions 96
Test principle Magnetic bead extraction for the isolation of high-quality RNA from clinical swabs
Kit components

• 1x Magnetic Beads, 1.1 mL, store at 2 °C - 8 °C (Note: Do not freeze!).

• 1x Carrier Molecule, dissolved, 660 µL, store at 2 °C - 8 °C.

• 2x Proteinase K, dissolved, 520 µL, store at -20 °C.

• 1x Lysis buffer (LB), 12 mL, store at room temperature.

• 2x WB1, Wash buffer concentrate, 25 mL, store at room temperature.

• 2x WB2, Wash buffer concentrate, 16.5 mL, store at room temperature.

• 2x WB3, Wash buffer concentrate, 11 mL, store at room temperature.

• 1x Elution buffer, 6 mL, store at room temperature.

Equipment required

• 1x KingFisherTM Flex for automated RNA extraction (ThermoFisher Scientific cat. no. 5400600)
• 1x Single channel pipette (1 mL, 100 µL), (e.g. Transferpette® S 100 - 1000 µL, Brand®, Eurofins GeneScan Technologies GmbH, cat. no. 5617703301).
• 1x Single channel pipette (100 µL, 10 µL), (e.g. Transferpette® S 10 - 100 µL, Brand®, Eurofins GeneScan Technologies GmbH, cat. no. 5617703201).

Storage -20°C